 
    
    
        
        UB> Meter Readings> Edit
        
            Edit Meter Readings
         
        Summary
        
         
        The Edit Meter Readings window is used to edit specific unbilled meter readings by meter type and route. 
	The Edit Meter Readings window is generally used to modify specific meter 
	readings in a route after they have been generated or entered using the Input 
	New Meter Readings window (UB> Meter Readings> Input). The Edit Meter Readings 
	window can be used to modify the read date, meter reading, read period and read 
	year, or calculate an estimate on a single meter reading in a meter route. If 
	you would like to generate an estimated meter reading on all of the meters in a 
	route, use the Input New Meter Readings window (UB> Meter Readings> Input).
         
        Meter readings can also be modified from the Device Maintenance window (UB> Maintenance> Device), but there 
	you will only be able to modify the meter readings for one device at a time.
         
        Related Links
        
         
        Click here for information on entering a new meter reading.
        
         
        Step by Step
        
         
        1     Open the Edit Meter Readings window (UB> Meter Readings> Edit).
         
        2     Filter the displayed meter readings.  
 
            
                 
                
                    - Select a Meter Type and Route in the Parameters section and click the Refresh 
		icon  to display the unbilled meter readings in the window. The meter 
		readings will populate in the window. to display the unbilled meter readings in the window. The meter 
		readings will populate in the window.
 
         
         
        3     Edit the meter readings.  
 
            
                 
                
                    - Modify the values in the Read Date, Reading, Read Period, Read Year and/or Estimated Read field of any of the meter 
		readings in the window.
- Highlight a meter reading and click the Modify icon  to open the Account Master Maintenance window of the 
		customer account attached to the selected meter. to open the Account Master Maintenance window of the 
		customer account attached to the selected meter.
- Highlight a reading and click the Delete icon  to delete the selected meter reading. to delete the selected meter reading.
- Highlight a meter reading and select an estimate option from the
		Process icon  drop-down menu   to generate an estimated meter reading on the selected meter. drop-down menu   to generate an estimated meter reading on the selected meter.
                        - Select Use Prior Year if you would like to use the consumption of the same period in the 
			previous year as the estimate of the current reading. If the meter does 
			not have a reading in the same period in the last year, the reading will 
			default to the prior reading on the meter.
- Select Use Prior Period if you would like to estimate the new meter reading based on the 
			consumption during the last meter read period (consumption will be 
			estimated based on meter read period, not meter read date). This method 
			will add the consumption during the previous meter read period to the 
			last meter reading to calculate the new meter reading and consumption. 
			For example, if the previous period consumption and meter reading was 
			1000 and 12,000, the estimated reading will be 13,000 with consumption 
			of 1000 units.
                            - If there are multiple readings during the previous meter read period, those meter 
				readings will be added together to determine the estimated amount.
- If a meter was not read during the previous period, the meter reading will default 
				to the last reading that was read on the meter, and the consumption 
				will default to zero. If there is not a meter reading during the 
				previous meter read period, an Expand button will display next to 
				the meter reading.
- If you would like to generate the estimate based on the last read period rather 
				than the meter read of the last period, select Last Period Read in 
				the Estimate Method drop-down menu.
- Select Last Period Read if you would like to estimate the consumption based on the last 
			billed meter reading. This varies from the User Prior Period selection 
			because this option will use any previous billed meter reading, not just 
			the meter reading of the previous period.
                            - For example, if you are in billing period 06 and a meter was not read in period 
				05, the consumption will be calculated based on the consumption 
				billed during period 04. If the meter had 500 units of billed 
				consumption in period 04, the consumption in period 06 will be 
				estimated at 500 and the meter reading will be 500 units plus the 
				previous reading on the meter.
- Select Winter Average if you would like to use the last calculated and committed 
			winter average on a meter to estimate the consumption. If no winter 
			average is found on the meter or the calculated winter average has not 
			been committed, the reading will default to the prior reading on the 
			account.
                            - If there are multiple winter averages on the customer account, the consumption 
				will calculated based on the winter average with the most recent 
				winter average effective date (UB> Maintenance> Account> Winter Averages tab> Effective Date field). 
				This applies even if the winter average effective date is in the 
				future. This means winter averages that have still not reached their 
				effective dates will be used to calculate the consumption.
- Select Multiply EDU’s if you would like to calculate the consumption based on the meter 
			EDU’s attached to the meters in the route. When this option is selected, 
			a field titled EDU Multiplier will become visible.
                            - A meter EDU is entered on a device using the Device Maintenance window (UB> 
				Maintenance> Device> Connections tab> EDU column).
- The Multiply EDU option will multiply the value in the EDU Multiplier 
				field by the value in the EDU field on the meter to calculate 
				the consumption on the meter. For example, if you enter 100 in the 
				EDU Multiplier field and the meter has an EDU of 4, the consumption 
				will be calculated at 400 units.
- Click the Recalculate icon  after selecting an estimate method to recalculate the consumption on 
			the meter. after selecting an estimate method to recalculate the consumption on 
			the meter.
- The Variance column will display the variance between the 
		consumption on the new reading and the consumption on the meter reading 
		in the same meter period during the previous year. The formula for the 
		Variance column is:
 
                
                    
                    
                    
                    
                    
                    
                        
                            | (Larger Consumption - Smaller Consumption) | X | 100 | = | Variance % | 
                        
                            | Smaller Consumption | 
                    
                
                 
                
                    - Click the Save icon  when complete to save the changes to the meter reading. when complete to save the changes to the meter reading.
 
         
         
        
        Springbrook Software
        
        ® All Rights Reserved 2018
        Toll Free Support 866-777-0069